>>Publications Index
>>Site TOP

Belle Technical Journal Publications

|| EFC || SVD || CDC || ACC || TOF || ECL || ZDLM/Sol. || KLM || DAQ || Trigger || Computing || Analysis ||

1. The Belle detector
  A.Abashian et al.[NIM A479,117 (2002)], [KEK Progress Report 2000-4]
[ source files (Belle only)]


EFC
1. Detection of minimum-ionizing particles and nuclear counter effect with pure BGO and BSO crystals with photodiode readout
  K. Ueno et al.[Nucl.Instrum.Meth. A396: 103-109, April 1997]
[physics/9704013]
2. Radiation hardness of undoped BGO crystals
  S. K. Sahu et al.[Nucl.Instrum.Meth. A388: 144-148, March 1997]
 

[BELLE-PREPRINT-96-7]

3. Performance of undoped BGO crystals under extremely high dose conditions
  K. C. Peng et al.[ Nucl.Instrum.Meth. A427: 524-527, May 1999]
4. Measurement of radiation damage on an optical reflector
  K. C. Peng et al. [ Nucl.Instrum.Meth. A384: 544-546, January 1997 ]


SVD
1. The BELLE silicon vertex detector trigger
  SVD Collaboration [Nucl.Instrum.Meth.A511:153-156,September 2003]
2. The BELLE silicon vertex detector
  Y. Ushiroda (KEK, Tsukuba) [Nucl.Instrum.Meth.A511:6-10,September 2003]
3. The Belle silicon vertex detector: present performance and upgrade plans
  G. Taylorv et al. [Nucl.Instrum.Meth.A501:22-31,March 2003]
4. IMPROVEMENT OF RADIATION HARDNESS OF DOUBLE-SIDED SILICON STRIP DETECTOR FOR BELLE SVD UPGRADE.
  J. Kaneko et al. [IEEE Trans.Nucl.Sci.49:1593-1597,2002]
5. The BELLE silicon vertex detector
  T. Kawasaki (Niigata U.) [Nucl.Instrum.Meth.A494:94-101,November 2002]
6. PERFORMANCE OF THE BELLE SILICON VERTEX DETECTOR
  R. Abe et al. [IEEE Trans.Nucl.Sci.48:997-1001,2001]
7. Performance of the Belle silicon vertex detector
  M. Hazumi (Osaka U.) [Nucl.Instrum.Meth.A473:1-6,November 2001]
8. THE BELLE SILICON VERTEX DETECTOR
  Hiroaki Aihara (Tokyo U.) []
[hep-ex/0011028]
9. The BELLE silicon vertex detector
  BELLE Collaboration (G. Alimonti et al.) [Nucl.Instrum.Meth.A453:71-77,October 2000]
10. The silicon vertex detector for BELLE
  T. Tsuboyama (KEK, Tsukuba) [Nucl.Instrum.Meth.A447:26-34,June 2000]
11. A control and readout system for the BELLE silicon vertex detector .
  M. Tanaka (KEK, Tsukuba), M. Hazumi, J. Ryuko, K. Sumisawa (Osaka U.) ,D. Marlow (Princeton U.) [Nucl.Instrum.Meth.A432:422-431,1999]
[KEK-PREPRINT-98-229]
12.

BELLE silicon vertex detector

  M. Hazumi (Osaka U.) [Nucl.Instrum.Meth.A379:390-392,1996]
13. IMPROVEMENT OF RADIATION HARDNESS OF DOUBLE-SIDED SILICON STRIP DETECTOR FOR BELLE SVD UPGRADE.
  J. Kaneko et al. [IEEE Trans.Nucl.Sci.49:1593-1597]
14. Status of the Belle SVD detector
  R. Abe et al. [Nucl.Instrum.Meth.A478:296-298,February 2002 ]
15. Trigger Timing Module for SVD2 upgrade at Belle.
  M. C. Chang et al. [Nucl.Instrum.Meth.A513:559-565,November 2003]
Retern to Page Top
CDC
1. The BELLE central drift chamber
  S. Uno [Nucl.Instrum.Meth.A379:421-423,September 1996]
2. A high-resolution cylindrical drift chamber for the KEK B-factory
  H. Hirano et al.[Nucl.Instrum.Meth.A455:294-304,December 2000] [Belle-preprint 2000- 1]
3. Study of a drift chamber filled with a helium-ethane mixture
  S. Uno et al.[Nucl.Instrum.Meth.A330:55-63,June 1993]
4. Cathode image readout in the BELLE central drift chamber
  M. Akatsu et al. [Nucl.Instrum.Meth.A454:322-333,November 2000]
5. Drift Velocity of Electrons in Helium-Based Gas Mixture Measured with
a UV Laser
  O.Nitou, K.Takahashi, T.Shinomura, O.Tsumura, and S.Uno, JPN.J.Appl. Phys. 33 (1994) 5929
6. Study of dE/dx in a Drift Chanber with He-C2H6 Gas Mixture
  K.Emi et al., J. Phys. Soc. Jpn. 65(1996) 657;
7. Study of a dE/dx measurement and the gas-gain saturation by a prototype drift chamber for the BELLE-CDC
  K.Emi et al. [Nucl.Instrum.Meth.A379:225-231,September 1996]
8. Test of charge-to-time conversion and multi-hit TDC technique for the BELLE CDC readout
  Y. Fujita et al. [Nucl.Instrum.Meth.A405:105-110,March 1998] [Belle-preprint 97-6]


ACC
1. Aerogel Cherenkov counter for the BELLE experiment
  T. Iijima et al. [Nucl.Instrum.Meth.A379:457-459,September 1996]
2. Silica aerogel Cherenkov counter for the KEK B-factory experiment
  T. Sumiyoshi et al. [Nucl.Instrum.Meth.A433:385-391,August 1999]
3. Study on fine-mesh PMTs for detection of aerogel Cherenkov light
  T. Iijima et al. [Nucl.Instrum.Meth.A387:64-68,March 1997]
4. Study of a threshold Cherenkov counter based on silica aerogels with low refractive indices
  I. Adachi et al. [Nucl.Instrum.Meth.A355:390-398,February 1995]
[hep-ex/9412008]
5. Measurement of radiation damage on a silica aerogel Cherenkov radiator
  S. K. Sahu et al. [Nucl.Instrum.Meth.A382:441-446,November 1996]
[hep-ex/9604004]
6. Feasibility study of single-photon counting using a fine-mesh phototube for an aerogel readout
  R. Enomoto et al. [Nucl.Instrum.Meth.A332:129-133,July 1993]
[hep-ex/9412010]
7. The monitoring system for the aerogel Cherenkov counter of the BELLE detector
  M. H. R. Khan et al. [Nucl.Instrum.Meth.A413:201-212,August 1998]; erratum A432(1999)544
[hep-ex/9803027]
8. Monte-Carlo simulation for an aerogel Cherenkov counter
  R. Suda et al. [Nucl.Instrum.Meth.A406:213-226,April 1998]
[hep-ex/9707042]
9. Aerogel Cherenkov counter for the BELLE detector
  T. Iijima et al. [Nucl.Instrum.Meth.A453:321-325,October 2000]
Retern to Page Top

TOF
1. Timing characteritics of a micro-channel plate and fine mesh photomultiplier tubes in a 1 T field
  H. Kichimi et al. [Nucl.Instrum.Meth.A325:451-457,February 1993]
2. The BELLE TOF system
  H. Kichimi et al. [Nucl.Instrum.Meth.A453:315-320,October 2000]
3. KEKB Beam Collision Stability at the Picosecond Timing and Micron Position Resolution as observed with the Belle Detector
  H. Kichimi et al. [ Journal of Instrumentation, 5, P03011 (2009) ]
[arXiv:1001.1194 ]


ECL
1. Beam test of the CsI(Tl) calorimeter for the BELLE detector at the KEK-B factory
  Y. Ohshima et al. [Nucl.Instrum.Meth.A380:517-523,October 1996]
2. DEVELOPMENT AND EVALUATION OF CHARGE SENSITIVE PREAMPLIFIER FOR CSI CALORIMETER IN THE KEK B FACTORY
  M. Tanaka et al. [IEEE Trans.Nucl.Sci.41:1208-1211,1993][Scanned images: 199327156]
[KEK-PREPRINT-93-156]
3. Study of the radiation hardness of CsI(Tl) crystals for the BELLE detector
  K. Kazui et al. [Nucl.Instrum.Meth.A394:46-56,July 1997]
4. Study of the BELLE CsI calorimeter prototype with the BINP tagged photon beam
  V. M. Aulchenko et al. [Nucl.Instrum.Meth.A379:491-494,September 1996]
5. Study of characteristics of the BELLE CsI calorimeter prototype with a BINP tagged photon beam
  H. S. Ahn et al. [Nucl.Instrum.Meth.A410:179-194,June 1998]
6. A detailed test of the CsI(T) calorimeter for BELLE with photon beams of energy between 20 MeV and 5.4 GeV
  H. Ikeda et al. [Nucl.Instrum.Meth.A441:401-426,March 2000]
[BELLE-PREPRINT-99-3]
7. Tests of cesium iodide crystals for an electromagnetic calorimeter
  E. Blucher et al. [Nucl.Instrum.Meth.A249:201,September 1986]
8. The CsI(Tl) e.m. Calorimeter for the BELLE Experiment at KEK
  M.H.Lee, Proceedings of the Sixth Int. Conf. on Calorimetry in High Energy Physics, Frascati, Italy, June 1996, p. 695.
9. Present Status of the BELLE CsI(Tl) Calorimeter
  T.Tsukamoto, Proceedings of the Seventh Int. Conf. on Calorimetry in High
Energy Physics, Tucson, Arizona, USA, November 1997, p.82.
10. CsI(Tl) Calorimeter for BELLE
  B.G.Cheon, Proceedings of the Eighth Int. Conf. on Calorimetry in High
Energy Physics, Lisbon, Portugal, June 1999, p.197.
11. The Belle CsI calorimeter
  H.Sagawa [Nucl. Instr. Meth. A453:259 October 2000]
12. Status and Performance of the BELLE Electromagnetic Calorimeter
  A.Kuzmin, Proceedings of the Ninth Int. Conf. on Calorimetry in High
Energy Physics, Annecy, France, October 2000, p.645.
13. Belle electromagnetic calorimeter
  K.Miyabayashi, [Nucl. Instr. Meth. A494 : 298, November 2002]
14. Electromagnetic calorimeter trigger at Belle
  B.G.Cheon et al., [Nucl. Instr. Meth. A494:548, November2002]
15. Performance and Upgrade Plans of the Belle Calorimeter
  B.A.Shwartz, Proceedings of the Tenth Int. Conf. on Calorimetry in
High Energy Physics, Pasadena, California, USA, March 2002, p.182.
16. Monitoring and Calibration of the Belle Electromagnetic Calorimeter
  K.Miyabayashi, Proceedings of the Tenth Int. Conf. on Calorimetry in
High Energy Physics, Pasadena, California, USA, March 2002, p.394.
17. Study of charactyeristics of the Belle CsI calorimeter prototype with
a BINP tagged photon beam
  H.S. Ahn et al., [Nucl. Instr. and Meth. A410:179-194, June1998)]
Retern to Page Top

ZDLM/Solenoid
1. Real-time Luminosity Monitor for a B-factory Experiment.
  T. Hirai, S. Uehara and Y. Watanabe. [Nucl. Instrum. Meth. A458:670, February 2001]
[submitted draft]
2. Magnetic field mapping of the Belle solenoid.
  N. Tan et al. [ IEEE Trans.Nucl.Sci.48:900-907, June 2001]


KLM
1. The KL/mu Detector Subsystem for the BELLE Experiment at the KEK B-factory
  A.Abashian et al. [ Nucl. Instrum. Meth. A449: 112-124 (2000) ]
[submitted draft]
2. Muon Identification in the Belle Experiment at KEKB
  A.Abashian et al., [Nucl. Instrum. Meth. A491: 69-82, September 2002]
[submitted draft]
3. Performance of glass RPC operated in streamer mode with SF_6 gas mixture
  K. Abe et.al., [Nucl. Instrum. Meth. A455: 397-404, December 2000]
4. A SEARCH FOR A FREONLESS GAS MIXTURE FOR GLASS RPC.
  A. Yamaguchi et al.,[IEEE Trans.Nucl.Sci.48:893-899,2001]


DAQ
1. Development of event building farm for SuperKEKB
  K.Itoh et al., [IEEE Trans. Nucl. Sci. 53, 293 (2006)]
2. Serial-Bus Based Trigger Timing Distribution System for SuperBelle
  M.Nakao and M.Tanaka, [IEEE Trans. Nucl. Sci. 52, 1196 (2005)]
3. Modular Pipeline Readout Electronics for the SuperBelle Drift Chamber
  T.Higuchi et al., [IEEE Trans. Nucl. Sci. 52, 1912 (2005)]
4. The Data Acquisition System Based on PMC bus
  Y.Igarashi et al., [eConf C0303241:TUGP009 (2003)]
5. Development of a PCI Based Data Acquisition Platform for High Intensity Accelerator Experiments
  T.Higuchi et al., [eConf C0303241:TUGT004 (2003)]
6. Belle DAQ System Upgrade at 2001
  S.Y. Suzuki, R.Itoh, H.W.Kim, H.J.Kim, H.O.Kim, M.Nakao, E.Won, and M.Yamauchi, [Nucl. Instrum. Meth. A494, 535 (2002) ]
7. Switchless Event-building Farm for the Belle Data Acquisition System
  M.Nakao, R.Itoh, S.Y.Suzuki, M.Yamauchi, E.Won, H.J.Kim, S.H.Roh, H.W.Kim, H.O.Kim, and S.Yanaka, [IEEE Trans. Nucl. Sci. 48, 2385 (2001)]
8. The Belle DAQ System
  S.Y.Suzuki , M.Yamauchi , M.Nakao, R.Itoh, and H.Fujii, [Nucl. Instrum. Meth. A453, 440 (2000)]
9. Data Acquisition System for the Belle Experiment
  Belle Collaboration (M.Nakao et al.), [IEEE Trans. Nucl. Sci. 47, 56 (2000)]
10. The Belle Event Building System
  S.Y.Suzuki, H.Matsuo, H.Fujii, O.Sasaki, Y.Igarashi, Y.Nagasaka, Y.Watase, H.Sakamoto, M.Tairadate, [IEEE Trans. Nucl. Sci. 47, 61 (2000)]
11. Network Shared Memory Framework for the Belle Data Acquisition Control
  M.Nakao and S.Y.Suzuki, [IEEE Trans. Nucl. Sci. 47, 267 (2000)]
12. Data Acquisition System for Belle
  M.Nakao, [Nucl. Instrum. Meth. A379, 539 (1996)]


Trigger
1. Development of the central trigger system for the BELLE detector at the KEK B-factory
  Y. Ushiroda et al. [Nucl.Instrum.Meth.A438:460-471,December 1999]
[BELLE-PREPRINT-99-1]
2. Z-trigger system with the BELLE Central Drift Chamber
  M. Tomoto et al. [Nucl.Instrum.Meth.A447:416-423,June 2000]
[BELLE-PREPRINT-99-2]
3. A fast programmable trigger for isolated cluster counting in the BELLE
experiment
  H. J. Kim et al. [Nucl.Instrum.Meth.A457:634 (2001)]
[physics/9911050]
4. Electromagnetic calorimeter trigger at Belle
  B.G.Cheon et al., [Nucl. Instr. Meth. A494:548, November2002]


Computing
1. Belle computing system
  I.Adachi et al. [Nucl.Instrum.Meth.A534:53-58,December 2004]


Analysis
1. Electron identification in Belle
  K.Hanagaki et al., [Nucl. Instrum. Meth. A485:490-503,June 2002]
2. Muon Identification in the Belle Experiment at KEKB
  A.Abashian et al., [Nucl. Instrum. Meth. A491: 69-82, September 2002]
[submitted draft]
3. Proper-time Resolution Function for Measurement of Time Evolution of
B Mesons at the KEK B-Factory
  H.Tajima et al., [Nucl. Instrum. Meth. A533: 370,2004]
[hep-ex/0301026]
4. Neutral B Flavor Tagging for the Measurement of Mixing-induced CP Violation at Belle
  H.Kakuno et al, [Nucl. Instrum. Meth. A533: 516,2004]
[hep-ex/0403022]
5. A Hierarchical NeuroBayes-based Algorithm for Full Reconstruction of B Mesons at B Factories
  M.Feindt et al, [Nucl. Instrum. Meth. A654: 432 (2011)]
[ arXiv:1102.3876]


|| EFC || SVD || CDC || ACC || TOF || ECL || ZDML || KLM || DAQ || Trigger || Analysis ||

Retern to Page Top